Catálogo Hanna Instruments V31
edge®blu *
Specifications
2
Range 2
-2.00 to 16.00 pH; -2.000 to 16.000 pH †
Resolution
0.01 pH; 0.001 pH †
Accuracy (@25°C/77°F)
±0.01 pH; ±0.002 pH †
Basic mode: Automatic, up to 3 points calibration 5 standard buffer Standard mode: Automatic up to 5 points calibration 7 standard buffers (1.68 † , 4.01 or 3.00, 6.86, 7.01, 9.18, 10.01, 12.45 † ) and 2 custom buffers †
pH
Calibration
Temperature Compensation 2
automatic, -5.0 to 100.0°C (23.0 to 212.0°F) (using integral temperature sensor)
Electrode Diagnostics
standard mode: probe condition, response time, and out of calibration range
Range
±1000 mV
mV pH
Resolution
0.1 mV
±0.2 mV
Accuracy (@25°C/77°F)
Range 2
-20.0 to 120.0°C; -4.0 to 248.0°F
Temperature
Resolution
0.1°C; 0 .1°F
±0.5°C; ±0.9°F
Accuracy
pH
Probe
HI11102 HALO® glass body pH electrode with Bluetooth® Smart technology
up to 1000 † (400 for basic mode) records organized in: manual log-on-demand (max. 200 logs), manual log-on-stability (max. 200 logs), interval logging † (max. 600 samples; 100 lots)
Logging
Connectivity Environment Power Supply
1 USB port for storage; 1 micro USB port for charging and PC connectivity
Additional Specifications
0 to 50°C (32 to 122°F); RH max 95% non-condensing
5 VDC adapter (included)
202 x 140 x 12 mm (7.9” x 5.5” x 0.5”)
Dimensions
Weight
250 g (8.82 oz.)
HI2202-01 (115V) and HI2202-02 (230V) edge blu includes: HI11102 HALO pH electrode with Bluetooth® Smart technology, pH 4 buffer solution sachets (4), pH 7 buffer solution sachets (2), pH 10 buffer solution sachets (2), electrode cleaning solution sachets (2), battery for HALO, benchtop docking station with electrode holder, wall-mount cradle, USB cable, 5 VDC power adapter, quality certificates and instruction manual.
Ordering Information
Hanna Lab App Specifications*
HALO Specifications HI11102 HALO (included) Reference double, Ag/AgCl Junction ceramic Electrolyte gel
-2.000 to 16.000 pH ±800 mV -20.0 to 120.0°C (-4.0 to 248.0°F)
Range 2
0.1; 0.01; 0.001 pH 1; 0.1 mV 0.1°C (0.1°F) ±0.005 pH ±0.3 mV ±0.5°C (±1.0°F)
0.00 to 12.00 pH ±420 mV
Range
Resolution
edge ® blu
Bulb Shape
spheric
Outer Diameter (glass)
12 mm (glass)
Accuracy (@25°C/77°F)
Overall Length
183 mm
-5.0 to 80.0°C (23.0 to 176.0°F)
Solution Temperature
up to five-point calibration with seven standard buffers (1.68, 3.00 or 4.01, 6.86, 7.01, 9.18, 10.01, 12.45 pH)
Body Material
glass
Calibration Points
0.0 to 50.0°C (32.0 to 122.0°F), electronic module is not waterproof
Environment
Temperature Compensation 2
automatic from -5.0 to 100.0°C; 23.0 to 212.0°F
Temperature Sensor
integrated
Bluetooth® Smart (Bluetooth® 4.0), 10 m (33’) range CR2032 3V lithium ion / approximately 500 hours
Connection
Compatibility/System Requirements
see www.hannainst.com for latest compatibility requirements
Battery Type / Life
Download Information
Apple, theApple logo, iPhoneand iPadare trademarksofApple Inc., registered in theU.S.andothercountries.AppStore isaservicemarkofApple Inc. TheBluetooth®wordmarkand logosare registered trademarksownedbyBluetoothSIG, Inc.
2Limitswillbe reduced toactualprobe/sensor limits. *HALO required formeasurementuse. †Standardmodeonly
www.hannainst.com |
2.13
pH solutions begin on page 2.136
Made with FlippingBook